Impact of LM Innovation technology on limescale deposits
Case study
Field test: Water quality
PAPETERIES DU LEMAN
Publier (74)
June 2024 → July 2024
Protocol
- Laboratory tests carried out by an R&D engineer
- 15 uses of 2 kettles containing 1 L hard water (TH: 25 °f) LM and TEMOIN
- Kettles like new from the start
Observation
Visually, there are fewer limescale deposits in the kettle used with LM water.
TEMOIN water kettle (after 15 uses)
LM water kettle (after 15 uses)
Conclusion
LM technology transforms limestone in the form of calcite into aragonite: it remains in solution in the water, crystallizes less, deposits less on equipment and is easier to remove.